Packer Element High Pressure and High Temperature Setting Test
The packer element of retrievable packer take the high pressure and high temperature setting test to insure the capability of the packer, the Packer elements need to be replaced if the testing done before shipment.
Packer Element Test from Below
* Apply 26,000lbs.-33,000lbs. (115.6KN-146.7KN) to the top end of the packer to fully-set
it inside the test fixture. Bleed off the air as much as possible.
* Increase pressure in the annulus below the packer elements to a minimum of
12,300psi(84.8Mpa). Hold test pressure for a minimum of 15 minutes. No leaks are
acceptable.
Packer Setting Test
After test to disassemle the packer to check the element